The utility of measuring tear film break-up time for prescribing contact lenses.

2017

Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then cont…

0301 basic medicineAdultMalemedicine.medical_specialtyVisual acuityVisual Acuitylaw.invention03 medical and health sciencesYoung Adult0302 clinical medicineCLs upper limitslawOphthalmologyEye healthmedicineHumansmedicine.diagnostic_testBlinkingbusiness.industryCorneal TopographyQuality measurementGeneral MedicineTear film break-up timeCorneal topographyContact Lenses Hydrophiliceye diseasesLens (optics)Ophthalmology030104 developmental biologyPrescriptionsTears030221 ophthalmology & optometryTearsFemalemedicine.symptombusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

What is the influence of parents' myopia on their children's myopic progression? A 22-year follow-up study.

2016

Purpose To study the connection between parental myopia and their children's myopia from school age to adulthood. Methods Two hundred and forty myopic schoolchildren (119 boys, 121 girls, mean age 10.9 years) with no previous spectacles for myopia were recruited to a 3-year treatment trial with different use of spectacles. Follow-ups were performed at mean ages of 13.9, 23.7 and 33.2 years for 238, 176 and 170 subjects respectively. Subjective refraction was calibrated to the spherical equivalent at corneal level (SEcor). Corneal refractive power (CR) and axial length (AL) were measured. Parental myopia was assessed with a questionnaire and the children assigned accordingly to one of three …

0301 basic medicineMaleParentsPediatricsgenetic structuresSpherical equivalentCornea0302 clinical medicineChild of Impaired ParentsSurveys and Questionnairesfollow-upMyopiaYoung adultChildSchool age childFollow up studiesta3142General MedicineAxial lengthcorneal refractionAxial Length EyeEyeglassesDisease ProgressionFemaleAdultmedicine.medical_specialtyAdolescentheredityaxial lengthRefraction Ocular03 medical and health sciencesYoung AdultTreatment trialmedicineHumansGenetic Predisposition to Diseasebusiness.industrySignificant differenceCorneal TopographySubjective refractioneye diseasesta3125Ophthalmology030104 developmental biology030221 ophthalmology & optometryOptometryprogressionsense organsbusinessFollow-Up StudiesActa ophthalmologica
researchProduct

Genome-wide association meta-analysis of corneal curvature identifies novel loci and shared genetic influences across axial length and refractive err…

2020

Corneal curvature, a highly heritable trait, is a key clinical endophenotype for myopia - a major cause of visual impairment and blindness in the world. Here we present a trans-ethnic meta-analysis of corneal curvature GWAS in 44,042 individuals of Caucasian and Asian with replication in 88,218 UK Biobank data. We identified 47 loci (of which 26 are novel), with population-specific signals as well as shared signals across ethnicities. Some identified variants showed precise scaling in corneal curvature and eye elongation (i.e. axial length) to maintain eyes in emmetropia (i.e. HDAC11/FBLN2 rs2630445, RBP3 rs11204213); others exhibited association with myopia with little pleiotropic effects …

0301 basic medicinegenetic structuresMedicine (miscellaneous)EmmetropiaGenome-wide association studyVARIANTSGenome-wide association studiesSensory disorders Donders Center for Medical Neuroscience [Radboudumc 12]Cornea0302 clinical medicineRisk FactorsCorneaDatabases GeneticMULTIPLEMyopiaGene Regulatory NetworksEXPRESSION PATTERNS10. No inequalitylcsh:QH301-705.5POPULATIONGeneticseducation.field_of_studymedicine.diagnostic_testHERITABILITYCorneal DiseasesAsian Continental Ancestry Group ; Axial Length Eye ; Cornea ; Corneal Topography ; Databases Genetic ; European Continental Ancestry Group ; Gene Regulatory Networks ; Genetic Loci ; Genetic Predisposition to Disease ; Genome-Wide Association Study ; Humans ; Myopia ; Phenotype ; Polymorphism Single Nucleotide ; Refractometry ; Risk Assessment ; Risk FactorsCorneal topographyEYE SIZE3. Good healthAxial Length EyePhenotypemedicine.anatomical_structureGeneral Agricultural and Biological SciencesExtracellular matrix organizationKeratoconusCorneal diseasesPopulationBiologyPolymorphism Single NucleotideRisk AssessmentArticleWhite PeopleGeneral Biochemistry Genetics and Molecular BiologyOCULAR COMPONENT DIMENSIONS03 medical and health sciencesSPHERICAL EQUIVALENTAsian PeoplemedicineHumansGenetic Predisposition to DiseaseKERATOCONUS3125 Otorhinolaryngology ophthalmologyeducationCorneal Topographymedicine.diseaseCOLLAGENeye diseasesRefractometry030104 developmental biologylcsh:Biology (General)Genetic LociRE3111 Biomedicinesense organs030217 neurology & neurosurgeryGenome-Wide Association StudyCommunications Biology
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Corrigendum to “Short-term changes in light distortion in orthokeratology subjects"

2015

Artigo completo publicado na revista "BioMed Research International, (2015), 1-7" e disponível no RepositóriUM em: http://hdl.handle.net/1822/33375

AdultMaleAdolescentLightmedicine.medical_treatmentVisual AcuityLentes de contactolcsh:MedicineBioinformaticsGeneral Biochemistry Genetics and Molecular BiologyContrast SensitivityCorneaYoung AdultDistortionMyopiamedicineHumansÓpticaScience & TechnologyGeneral Immunology and Microbiologybusiness.industrylcsh:ROrthokeratologyCorneal TopographyGeneral MedicineRefractive ErrorsTerm (time)OptometryFemaleCorrigendumbusinessOrthokeratologic Procedures
researchProduct

The relationship between central corneal thickness and Goldmann applanation tonometry

2003

The aim of this study was to investigate the relationship between Goldmann applanation tonometry and central corneal thickness in a large sample of healthy eyes.Five hundred eyes of 500 subjects (253 women, 50.6 per cent and 247 men, 49.4 per cent) were analysed in a prospective healthy population study. Mean age of the sample was 31 +/- 8 years. Goldmann applanation tonometry was carried out by one physician. Tonometric values were the mean of three consecutive readings. Subsequently, another physician carried out ultrasonic pachymetry with the DGH 2000 AP ultrasonic pachymeter (DGH Technology Inc, San Diego, USA). Ten measurements were made at the centre of the cornea of each eye. The low…

AdultMaleApplanation tonometrymedicine.medical_specialtyIntraocular pressureAdolescentgenetic structuresGoldmann applanation tonometryCorneaTonometry OcularOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedAnalysis of Variancebusiness.industryCorneal TopographyMiddle Agedeye diseasesLarge sampleOphthalmologyRegression AnalysisOptometryFemalesense organsbusinessOptometryClinical and Experimental Optometry
researchProduct

Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability

2001

Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…

AdultMaleBiometryLightInterobserver reliabilityAnterior ChamberEmmetropiaData descriptionCorneaOptical biometryOpticsMyopiaHumansReliability (statistics)AgedMathematicsObserver VariationReproducibilitybusiness.industryCorneal TopographyReproducibility of ResultsMiddle AgedSensory SystemsOphthalmologyInterferometryPartial coherence interferometryFemaleSurgerybusinessNuclear medicinePartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct